HALON MARKETING, LLC

Home Extinguishers Spra' Strip Master Series Radios/Speakers Battery Tender Garage Dollies 200 MPH Product Search New Items Special Offers Log In View Cart


Master Series Chassis Coating

MATERIAL SAFETY DATA SHEETS

Revised 7/95


Section I

Manufacturer's Name                                                                                                      Emergency Response #
PM Industries                                                                                                                        1-800-833-8933

Address                                                                                                                           Non -Emergency #
442 Ridge Road                                                                                                                     1-800-833-8933
West Milford, NJ 07480

Chemical Name & Synonyms                                                                                        Trade Name & Synonyms
Moisture Cure Polyurethane Coating                                                                        Master Series Custom Chassis Coating



Section II - Hazardous Ingredients
                                                                  Approx.
                                                                    %                                      TLV                                        CAS#

Diphenylmethane                                Less than 1.86                       OSHA: not established                  26447-40-5
Diisocyanate (MDI)                                                                          ACGIH.-not established


Non isomer specific CAS number includes 2,2' MDI and 2,4' MDI.

Polyisocyanate Based
                  MDI                                        32.4                               OSHA: not established*
                                                                                                     ACGIH: not established


*Specific chemical identity is withheld as a trade secret.

4,4'-Diphenylmethane
Diisocyanate (MDI)                                      8.5                               OSHA: 020 ppm ceiling-PEL           101-68-8
                                                                                                                            .200 mg/m3 ceiling
                                                                                                     ACGIH: .005 ppm TWA
         .                                                                                                                   .051 mg/m3 TWA

Aromatics 100                                            38.0                              OSHA: 50 ppm(245 mg/m3)            64742-95-6
                                                                                                                               For 8 hour workday

Aluminum                                                  18.4                                    10 mg/m3                                 7429-90-5


cwq984444ytyglyht78 This document is prepared pursuant to the OSHA Hazard Communication Standard (29 CFR 1910.1200). In addition, other substances not "hazardous" per this OSHA standard may be listed.


SECTION IV - FIRE AND EXPLOSION HAZARD DATA

 FLASH POINT:                                107 DEGREES F. TCC
 FLAMMABLE LIMITS:                        LEL              UEL
           AROMATIC 100                         0.9%            7.0%

 EXTINGUISHING MEDIA:   DRY CHEMICAL (E.G. MONOAMMONIUM, PHOSPHATE, POTASSIUM SULFATE, AND POTASSIUM CHLORIDE), CARBON DIOXIDE, HIGH EXPANSION (PROTEINIC) CHEMICAL FOAM, WATER SPRAY FOR LARGE FIRES.

SPECIAL FIRE FIGHTING PROCEDURES:  FULL EMERGENCY EQUIPMENT WITH SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE CLOTHING SHOULD BE WORN BY FIRE FIGHTERS.  DURING A FIRE, MDI VAPORS AND OTHER IRRITATING, HIGHLY TOXIC GASES MAY BE GENERATED BY THERMAL DECOMPOSITION OR COMBUSTION.  (SEE SECTION VII.)  AT TEMPERATURES GREATER THAN 400 DEGREES F.  (204 C), POLYMERIC MDI CAN POLYMERIZE AND DECOMPOSE WHICH CAN CAUSE PRESSURE BUILD UP IN CLOSED  CONTAINERS.  EXPLOSIVE RUPTURE IS POSSIBLE.  THEREFORE, USE COLD WATER TO COOL FIRE EXPOSED CONTAINERS.


SECTION 5 - HEALTH HAZARD DATA

 ROUTE OF ENTRY: SKIN CONTACT FROM LIQUID AND AEROSOLS (SPRAY APPLICATION) AND INHALATION.  ALTHOUGH MDI IS LOW IN VOLATILITY, AN INHALATION HAZARD CAN EXIST FROM MDI AEROSOLS OR VAPORS FORMED DURING HEATING, OR SPRAYING.

 HUMAN EFFECTS AND SYMPTOMS OF OVEREXPOSURE;
 ACUTE INHALATION:  MDI VAPORS OR MIST AT CONCENTRATIONS ABOVE THE TLV  CAN IRRITATE (BURNING SENSATION) THE MUCOUS MEMBRANES IN THE RESPIRATORY TRACT (NOSE, THROAT, LUNGS) CAUSING RUNNY NOSE. SORE THROAT, COUGHING. CHEST DISCOMFORT, SHORTNESS OF BREATH AND REDUCED LUNG FUNCTION (BREATHING OBSTRUCTION).  PERSONS WITH A PRE-EXISTING, NONSPECIFIC BRONCHIAL HYPERREACTIVITY CAN RESPOND TO CONCENTRATIONS BELOW THE TLV WITH SIMILAR SYMPTOMS AS WELL AS AN ASTHMA ATTACK.  EXPOSURE WELL ABOVE THE TLV MAY LEAD TO BRONCHITIS, BRONCHIAL SPASM AND PULMONARY EDEMA (FLUID IN LUNGS).  THESE EFFECTS ARE USUALLY REVERSIBLE.  CHEMICAL OR HYPERSENSITIVE PNEUMONITIS, WITH FLU-LIKE SYMPTOMS (E.G., FEVER, CHILLS) HAS ALSO BEEN REPORTED. SOLVENT VAPORS MAY BE IRRITATING TO THE EYES, NOSE AND THROAT.

CHRONIC INHALATION: AS A RESULT OF PREVIOUS REPEATED OVEREXPOSURES OR A SINGLE LARGE DOSE, CERTAIN INDIVIDUALS WILL DEVELOP ISOCYANATE SENSITIZATION (CHEMICAL ASTHMA) WHICH WILL CAUSE THEM TO REACT TO LATER EXPOSURE TO ISOCYANATE AT LEVELS WELL BELOW THE TLV.  THESE SYMPTOMS, WHICH INCLUDE; CHEST TIGHTNESS, WHEEZING, COUGH, SHORTNESS OF BREATH OR ASTHMATIC ATTACK, COULD BE IMMEDIATE OR DELAYED UP TO SEVERAL HOURS AFTER EXPOSURE.  SIMILAR TO MANY NON-SPECIFIC ASTHMATIC RESPONSES, THERE ARE REPORTS THAT ONCE SENSITIZED AN INDIVIDUAL CAN EXPERIENCE THESE SYMPTOMS UPON EXPOSURE TO DUST, COLD AIR OR OTHER IRRITANTS.  THIS INCREASED LUNG SENSITIVITY CAN PERSIST FOR WEEKS AND IN SEVERE CASES FOR SEVERAL YEARS.  CHRONIC OVEREXPOSURE TO ISOCYANATES HAS ALSO BEEN REPORTED TO CAUSE LUNG DAMAGE, INCLUDING DECREASE IN LUNG FUNCTION, WHICH MAY BE PERMANENT.  SENSITIZATION MAY BE EITHER TEMPORARY OR PERMANENT.  CHRONIC EXPOSURE TO ORGANIC SOLVENTS HAS BEEN ASSOCIATED WITH VARIOUS NEUROTOXIC EFFECTS INCLUDING PERMANENT BRAIN AND NERVOUS SYSTEM DAMAGE.  SYMPTOMS INCLUDE; LOSS OF MEMORY, LOSS OF INTELLECTUAL ABILITY AND LOSS OF COORDINATION.

ACUTE SKIN CONTACT: ISOCYANATES REACT WITH SKIN PROTEIN AND MOISTURE AND CAN CAUSE IRRITATION.  SYMPTOMS OF SKIN IRRITATION MAY BE REDDENING, SWELLING, RASH, SCALING OR BLISTERING. SOME PERSONS MAY DEVELOP SKIN SENSITIZATION FROM SKIN CONTACT.  CURED MATERIAL IS VERY DIFFICULT TO REMOVE. REPEATED OR PROLONGED SKIN CONTACT CAN RESULT IN DRY, DEFATTED AND CRACKED SKIN CAUSING INCREASED SUSCEPTIBILITY TO INFECTION.  IN ADDITION, SKIN IRRITATION (I.E. REDNESS, SWELLING), WHICH CAN DEVELOP INTO DERMATITIS.

CHRONIC SKIN CONTACT: PROLONGED CONTACT WITH THE ISOCYANATE CAN CAUSE REDDENING, SWELLING, RASH, SCALING OR BLISTERING.  IN THOSE WHO HAVE DEVELOPED A SKIN SENSITIZATION, THESE SYMPTOMS CAN DEVELOP AS A RESULT OF
CONTACT WITH VERY SMALL AMOUNTS OF LIQUID MATERIAL OR EVEN AS A RESULT OF VAPOR ONLY EXPOSURE.

ACUTE EYE CONTACT: LIQUID, AEROSOLS AND VAPORS OF THIS PRODUCT (ISOCYANATE AND SOLVENTS ) ARE IRRITATING AND CAN CAUSE TEARING, REDDENING AND SWELLING ACCOMPANIED BY A STINGING SENSATION AND/OR A FEELING LIKE THAT OF FINE DUST IN THE EYES.  IF LEFT UNTREATED, CORNEAL DAMAGE CAN OCCUR AND INJURY IS SLOW TO HEAL.   HOWEVER, DAMAGE IS USUALLY REVERSIBLE.

CHRONIC EYE CONTACT:   NONE FOUND.

ACUTE INGESTION:   CAN RESULT IN IRRITATION AND POSSIBLE CORROSIVE ACTION IN THE MOUTH, STOMACH TISSUE AND DIGESTIVE TRACT.   HOWEVER, IT IS NOT CONSIDERED A COMMON OCCUPATIONAL ROUTE OF EXPOSURE.

CHRONIC INGESTION:   NONE FOUND.

CARCINOGENICITY: NONE OF THE COMPONENTS OF THIS PRODUCT ARE LISTED BY THE NTP, IARC OR REGULATED BY OSHA AS CARCINOGENS.

MEDICAL  CONDITIONS
     AGGRAVATED BY EXPOSURE:  ASTHMA AND OTHER RESPIRATORY DISORDERS (BRONCHITIS, EMPHYSEMA, HYPERREACTIVITY), SKIN ALLERGIES, ECZEMA.
EXPOSURE LIMITS: NOT ESTABLISHED FOR PRODUCT AS A WHOLE.  REFER TO SECTION II FOR EXPOSURE LIMITS OF HAZARDOUS CONSTITUENTS.

EMERGENCY & FIRST AID PROCEDURES
EYE CONTACT: FLUSH WITH COPIOUS AMOUNTS OF LUKEWARM WATER FOR MINIMUM OF 15 MINUTES, WHILE LIFTING EYELIDS. CONTACT EYE PHYSICIAN FOR IMMEDIATE FOLLOW UP.

SKIN CONTACT:  REMOVE CONTAMINATED CLOTHING.  WASH SKIN THOROUGHLY WITH WATER AND SOAP.  WASH CONTAMINATED CLOTHING BEFORE REUSE. SEEK MEDICAL ATTENTION IF IRRITATION DEVELOPS OR PERSISTS.

INGESTION: DO NOT INDUCE VOMITING.  GIVE 1 TO 2 CUPS OF MILK OR WATER TO DRINK.  DO NOT GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS OR CONVULSING PERSON.  CONSULT A PHYSICIAN.

INHALATION: REMOVE TO FRESH AIR.  ADMINISTER OXYGEN OR ARTIFICIAL RESPIRATION AS NEEDED.  OBTAIN MEDICAL ATTENTION.  ASTHMATIC-TYPE SYMPTOMS MAY DEVELOP AND MAY BE IMMEDIATE OR DELAYED UP TO SEVERAL HOURS.  TREATMENT IS ESSENTIALLY SYMPTOMATIC.  CONSULT A PHYSICIAN.

NOTE TO PHYSICIAN
EYES: STAIN FOR EVIDENCE OF CORNEAL INJURY.  IF CORNEA IS BURNED, INSTILL ANTIBIOTIC/STERIOD PREPARATION FREQUENTLY.  WORKPLACE VAPORS COULD PRODUCE REVERSIBLE CORNEAL EPITHELIAL EDEMA IMPAIRING VISION.
SKIN:  THIS PRODUCT IS KNOWN SKIN SENSITIZER.  TREAT SYMPTOMATICALLY AS FOR CONTACT DERMATITIS OR THERMAL BURN.                                         
INGESTION: TREAT SYMPTOMATICALLY. THERE IS NO SPECIFIC ANTIDOTE.  INDUCING VOMITING IS CONTRAINDICATED BECAUSE OF THE IRRITATING NATURE OF THE PRODUCT.
INHALATION: THIS PRODUCT IS A KNOWN PULMONARY SENSITIZER.  TREATMENT IS ESSENTIALLY SYMPTOMATIC.  AN INDIVIDUAL HAVING A DERMAL OR PULMONARY SENSITIZATION REACTION TO THIS MATERIAL MUST BE REMOVED FROM ANY FURTHER EXPOSURE TO ANY ISOCYANATE.



SECTION VI - EMPLOYEE PROTECTION

REQUIRED WORK/HYGIENE PROCEDURES:  PRECAUTIONS MUST BE TAKEN SO THAT PERSONS HANDLING THIS PRODUCT DO NOT BREATHE VAPORS OR HAVE IT CONTACT THE EYES OR SKIN.  IN SPRAY OPERATIONS, PROTECTION MUST BE AFFORDED AGAINST EXPOSURE TO BOTH VAPOR AND SPRAY MIST.
EYE PROTECTION:  SAFETY GLASSES, SPLASH GOGGLES OR FACE SHIELD.  CONTACT LENSES SHOULD NOT BE WORN.
SKIN PROTECTION REQUIREMENTS: CHEMICAL RESISTANT GLOVES.   COVER AS MUCH OF THE EXPOSED SKIN AREA AS POSSIBLE WITH APPROPRIATE CLOTHING.   IF SKIN CREAMS ARE USED KEEP THE AREA COVERED TO A MINIMUM.
RESPIRATORY REQUIREMENTS: CONCENTRATIONS GREATER THAN TLV CAN OCCUR WHEN MDI IS SPRAYED, HEATED OR USED IN POORLY VENTILATED AREA.  IN SUCH CASE, OR WHENEVER CONCENTRATIONS OF MDI EXCEED THE TLV, RESPIRATORY PROTECTION
MUST BE WORN.  A POSITIVE PRESSURE, SUPPLIED AIR-RESPIRATOR OR SELF-CONTAINED BREATHING APPARATUS IS RECOMMENDED.  IN SITUATIONS WHERE MDI IS NOT SPRAYED, HEATED OR USED IN A POORLY VENTILATED AREA, AND A SUPPLIED AIR OR SELF CONTAINED BREATHING APPARATUS IS UNAVAILABLE OR ITS USE IMPRACTICAL, AT LEAST AN AIR-PURIFYING RESPIRATOR EQUIPPED WITH AN
ORGANIC VAPOR CARTRIDGE AND PARTICULATE PRE-FILTERS MUST BE WORN. HOWEVER, THIS SHOULD BE PERMITTED ONLY FOR SHORT PERIODS OF TIME AT RELATIVELY LOW CONCENTRATIONS (AT OR BELOW THE TLV).  HOWEVER, DUE TO THE POOR WARNING PROPERTIES OF MDI, PROPER FIT AND TIMELY REPLACEMENT OF FILTER ELEMENTS MUST BE ENSURED.  OBSERVE OSHA REGULATIONS FOR
RESPIRATOR USE (29 CFR 1910.134).
 VENTILATION  REQUIREMENTS:
EXHAUST VENTILATION SUFFICIENT TO KEEP THE AIRBORNE CONCENTRATIONS OF MDI AND SOLVENT BELOW THE RESPECTIVE TLV BE UTILIZED.  STANDARD REFERENCE SOURCE REGARDING INDUSTRIAL VENTILATION (I.E., ACGIH INDUSTRIAL VENTILATION) SHOULD BE CONSULTED FOR GUIDANCE ABOUT ADEQUATE VENTILATION.
ADDITIONAL PROTECTIVE MEASURES:
SAFETY SHOWERS AND EYEWASH STATIONS SHOULD BE AVAILABLE.  EDUCATE AND TRAIN EMPLOYEES IN SAFE USE OF PRODUCT.  FOLLOW ALL LABEL INSTRUCTIONS.



SECTION VII - REACTIVITY DATA

STABILITY:  STABLE UNDER NORMAL CONDITIONS.
HAZARDOUS POLYMERIZATION:  MAY OCCUR; CONTACT WITH MOISTURE AND OTHER MATERIALS WHICH REACT WITH ISOCYANATES OR TEMPERATURES OVER 400 DEGREES F. (204 C.) MAY CAUSE POLYMERIZATION.
 INCOMPATIBILITIES:  WATER MAY REACT TO FORM CARBON DIOXIDE.
AVOID CONTACT WITH WATER  ALSO AVOID AMINES, STRONG BASES, ALCOHOLS.  MATERIAL CAN CAUSE SOME CORROSION TO COPPER ALLOYS AND ALUMINUM.
INSTABILITY CONDITIONS:  CONTAMINATION WITH WATER.
DECOMPOSITION PRODUCTS;  BY HIGH HEAT AND FIRE: CARBON DIOXIDE, CARBON MONOXIDE, OXIDES OF NITROGEN, TRACES OF HCN AND MDI.


SECTION VIII - SPILL OR LEAK PROCEDURES

IF MATERIAL IS SPILLED: EVACUATE NONESSENTIAL PERSONNEL.  VENTILATE AREA. CONTROL FURTHER SPILLAGE IF FEASIBLE.  NOTIFY APPROPRIATE AUTHORITIES IF NECESSARY.  EQUIP CLEAN UP CREW WITH APPROPRIATE PROTECTIVE EQUIPMENT (SEE SECTION VI).  DIKE OR IMPOUND SPILLED MATERIAL. COVER THE SPILL WITH SAWDUST, VERMICULITE, FULLER'S EARTH OR OTHER ABSORBENT MATERIAL.  SHOVEL INTO SUITABLE UNSEALED CONTAINERS AND TRANSPORT TO WELL-VENTILATED AREA (OUTSIDE).  COVER LOOSELY.

WASTE DISPOSAL METHOD:  WASTE MUST BE DISPOSED OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL ENVIRONMENTAL CONTROL REGULATIONS.  INCINERATION IS PREFERRED METHOD.  EMPTY CONTAINERS MUST BE HANDLED WITH CARE DUE TO
PRODUCT RESIDUE.  DO NOT HEAT OR CUT EMPTY CONTAINER WITH ELECTRIC OR GAS TORCH.   (SEE SECTION IV AND VII) GASES MAY BE HIGHLY TOXIC.



SECTION IX - SPECIAL PRECAUTIONS & STORAGE DATA

STORAGE TEMPERATURE (MIN./ MAX.):  32 DEGREES F. (0 C.) / 122 DEGREES F. (50 C.)
SHELF LIFE: 12 MONTHS AT 77 DEGREES F. (25 C.) WHEN STORED IN SEALED CONTAINER.
SPECIAL SENSITIVITY:  IF CONTAINER IS EXPOSED TO HIGH HEAT, IT CAN BE PRESSURIZED AND POSSIBLY RUPTURE EXPLOSIVELY.  MDI REACTS WITH WATER TO FORM C02 GAS.  THIS GAS CAN CAUSE SEALED CONTAINERS TO EXPAND AND POSSIBLY RUPTURE EXPLOSIVELY.
HANDLING AND STORAGE PRECAUTIONS:  STORE IN TIGHTLY CLOSED CONTAINERS TO PREVENT MOISTURE CONTAMINATION. DO NOT RESEAL IF CONTAMINATION IS SUSPECTED.   AVOID CONTACT WITH SKIN AND EYES.   DO NOT BREATHE VAPOR. WARNING PROPERTIES (IRRITATION OF THE EYES, NOSE AND THROAT OR ODOR) ARE NOT ADEQUATE TO PREVENT CHRONIC OVEREXPOSURE FROM INHALATION.
THIS MATERIAL CAN PRODUCE ASTHMATIC SENSITIZATION UPON EITHER SINGLE INHALATION EXPOSURE TO A RELATIVELY HIGH CONCENTRATION OR UPON REPEATED INHALATION EXPOSURES TO LOWER CONCENTRATIONS.   EXPOSURE TO VAPORS OF HEATED MDI CAN BE EXTREMELY DANGEROUS. EMPLOYEE EDUCATION AND TRAINING IN THE SAFE USE AND HANDLING OF THIS PRODUCT ARE REQUIRED UNDER THE OSHA HAZARD COMMUNICATION STANDARD.



SECTION X - REGULATORY INFORMATION

DOT CLASSIFICATION- COMBUSTIBLE LIQUID
OSHA STATUS: THIS PRODUCT IS HAZARDOUS UNDER THE CRITERIA OF THE FEDERAL OSHA COMMUNICATION STANDARD 29 CFR 1910.1200.
SARA TITLE III:
         SECTION 311/212 HAZARDOUS CATEGORIES:
                 IMMEDIATE HEALTH HAZARD
                 DELAYED HEALTH HAZARD
                 FIRE HAZARD
                 REACTIVE HAZARD
         SECTION 313:
                  AROMATICS 100 (CAS#64742-95-6)
                  4,4'- DIPHENYLMETHANE DIISOCYANATE (CAS# 101-68-8)
CALIFORNIA PROPOSITION 65                                           
TO THE BEST OF OUR KNOWLEDGE, THIS PRODUCT CONTAINS NO LEVELS OF LISTED SUBSTANCES, WHICH THE STATE OF CALIFORNIA HAS FOUND TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE EFFECTS.

NOTICE:  THIS INFORMATION IS PRESENTED IN GOOD FAITH AND BELIEVED TO BE ACCURATE AS OF THE EFFECTIVE DATE BELOW.  HOWEVER, NO WARRANTY IS EXPRESS OR IMPLIED REGARDING THE ACCURACY OF THIS DATA OR THE RESULTS TO BE OBTAINED
 FROM THE USE THEREOF. PM INDUSTRIES ASSUMES NO RESPONSIBILITY FOR PERSONAL INJURY OR PROPERTY DAMAGE TO VENDEES, USERS OR THIRD PARTIES CAUSED BY THE MATERIAL, SUCH VENDEES OR USERS ASSUME ALL RISKS ASSOCIATED
WITH THE USE OF THE MATERIAL. REGULATORY REQUIREMENTS ARE SUBJECT TO CHANGE AND MAY DIFFER FROM ONE LOCATION TO ANOTHER; IT IS THE BUYER'S RESPONSIBILITY TO ENSURE THAT ITS ACTIVITIES COMPLY WITH FEDERAL, STATE, OR PROVINCIAL, AND LOCAL LAWS.  THE PRECEDING SPECIFIC INFORMATION IS MADE FOR THE PURPOSE OF COMPLYING WITH NUMEROUS FEDERAL, STATE OR PROVINCIAL AND LOCAL LAWS AND REGULATIONS.
 12/90

Top of Page

 

About Us Contact Us Privacy Policy FAQ'S
Event Schedule Distributorship Affiliates Home Restoration

Contact: Webperson  with questions or comments about this web site.   To order by phone call  800-343-9763
Last modified: 04/05/2008   All PRICES QUOTED IN U.S. DOLLARS
Copyright © 2003 by Halon Marketing, LLC  All rights reserved.